What would you like to see in this program?
Tell us now!
Please note
that when using the IPC-2152 with modifiers option, the amperage value has a slight drop at 10,20,30,40,50,60,70,80,90,100,200,300,400,500,600 & 700sqmils.
This is due to a multiplier used for each cross sectional area range.
All values are within +/-10% of the chart values however. If you do not
need to minimize conductor width on your PCB,
you can use the IPC-2152 without modifiers option where there is no
multiplier effect.
Product Revision Notes
Version 5.65 Updates & Additions:
Corrected imperial values for Conductor Spacing calculator in B3 mode
for 251-500V
Version 5.64 Updates & Additions:
Added PPM Calculator for crystal toloerance values.
Added Via
Thermal Resistance output to Via Properties.
Version 5.63 Updates & Additions:
Fixed startup error in Signal Properties calc in metric mode.
Added
Etch Factor note in Conductor Properties.
Added minimum width limit
to Conductor Width in
Conductor Properties calc to prevent a negative cross section value.
Version 5.62 Updates & Additions:
Removed conductor width derating and replaced it with conductor etch
factor.
Version 5.61 Updates & Additions:
Fixed metric wavelength value.
Version 5.6 Updates & Additions:
Fixed Edge Coupled Int Asym diff pair calc. (Had beta formula still in
code) Still a work in progess for this calc.
Added dB gain to
Conversion Data tab. (Still work in progress, more to come on this)
Version 5.5 Updates & Additions:
Added embedded resistors tab.
Fixed DC resistance in metric mode
for conductor calculator.
Version 5.4.1 Updates & Additions:
Corrected the embedded differential pair calculator.
Version 5.4 Updates & Additions:
Corrected the W/H and S/H error in the broadside differential pair
calculator. (B7)
Removed the T/H label from the CPW claculator. (B6)
Changed the "Top Side Conductor Percentage" to "Conductor Width
Derating" (B5) This may change again or go aways as we look for a
better way to handle this.
Changed stipline formula restriction to 0.1 < W/H <2.0. (B4)
Corrected improper location of "Invalid" flag in coplanar waveguide
calculator. (B4)
Corrected
outer pad diameter error in
padstack calculator for metric setting. (B3)
Fixed Er Eff decimal point issue. (B2)
Seperated fusing current from conductor properties calculator.
Added a "Solve for Condutcor Width" option for IPC-2151 without
modifiers and IPC-2221A calculators.
Repalced internal (hard
codeed) conductor trapazoid shape adjustment with settabe percentage
in options
Updated asymetric stripline calculator formula to Brian
C. Wadell formula.
Fixed IPC-2152 with modifiers not being selected
at program startup after user sets this option.
Fixed error message
in 2 layer via calculator when entering a larger than defaul value for
via hole diameter.
Version 5.32 Updates & Additions:
Added notes next to H1 / H2 in asymmetric stripline calculator.
Version 5.31 Updates & Additions:
Fixed outer pad diameter error in padstack calculator.
Fixed drill chart text wrap error.
Version 5.3 Updates & Additions:
Updated installer to support Windows 7.
Updated formulas for all of the conductor impedance models.
Updated formulas for all of the differential pair impedance models.
Added ability to include Er effective to the wavelength calculator.
Changed how the wire gauge calculator works, added max amps in air.
Added edge coupled embedded differential pair to calculator.
Added inches and um to conversion data.
Fixed "Enter copper weight manually" display issue.
Added imperial units to the minimum conductor spacing calculator.
Added indicator to show when differential impedance is within tolerance
of a target impedance.
Version 5.2 Updates & Additions:
Fixed Temprise & Ambient Temp enable / disable
when Fuse current vs. Time mode selected after user exists Conductor
Properties.
Fixed Temprise C vs. F scale.
Version 5.1 Updates & Additions:
Plating Thickness now disables when internal layer
is selected for conductor properties.
Plane Distance now disables when fuse current option is selected for
conductor properties
Added IPC version to options for conductor current.
Fixed Temprise F scale when 0C is selected.
Updated default values for via settings.
Version 5.0 Updates & Additions:
Significantly changed how the program calculates
amperage to better match the IPC-2152 charts.
Please note that the amperage value has a slight drop at
10,20,30,40,50,60,70,80,90,100,200,300,400,500,600 & 700sqmils.
This is due to the multiplier used for each cross sectional area range.
All values are within +/-10% of the chart values however.
Version4 series PCB Toolkit follows the new IPC-2152 chart as well but
uses the general chart which can be too conservative in some
applications. Implementing the new IPC-2152 has been no easy task since
no new formulas were produced in the document. This has forced us to
derive at our on formulas for current vs. temprise so please check back
often for updates to this V5 beta program.
Added microvia current vs.
temprise support
Added power dissipation in
dBm for via and conductor calculator
Added dual monitor support
for dialog boxes
Added broadside coupled
differential pair support
Added imperial units support
to spiral inductor calculator
Added embedded microstrip
support for conductor impedance
Added coplanar waveguide
support for conductor impedance
Added degree symbols
Fixed F to C conversion for
temprise
Fixed dropdown menu control
vs. tab control
Added close button to about dialog box
Fixed Conductor Impedance
selection list from B2
Added "Program Options" menu item for manually entering copper weight
Fixed install directory issue, now installs to V5 directory.
Added DC option for frequency input
Previous
Versions:
V4.0 Updates & Additions:
Updated current capacity
formulas per the new IPC-2152 specification
Comma
detection for European systems
Added units conversion tool
Invalid floating point in Impedances tool fixed
Added planar inductor calculator
Updated drill chart
Updated wire chart, added resistance, max amps
Added Power Delivery Network Impedance calculator
Added Thermal Resistance tools
PCB Thickness now included in current capacity
Added parallel conductors mode
Program Revision History
Version 4.6.1
Corrected copper plane thickness index when switching between
imperial and metric units.
Version 4.6
Corrected copper weight issue in the Impedances program for metric
stripline.
Plane thickness now shows metric weights when in metric mode.
Conductor temperatures properly read "N/A" when disabled.
Version 4.5
Added de-rating for fiberglass substrates for via and conductor
properties. This affects total amperage value due to substrates
having different thermal properties.
Corrected Microstrip / Stripline plating option error
Added conductor inductance to the conductor impedance calculator
Version 4.4
Added Carriage Return functionality for "Solve"
Fixed spelling errors in the padstack calculator
Updated Tab controls in programs
Version 4.3
Changed GUI to consolidate options
Added plane selection in conductor calculator
Version 4.2
Added more resolution to the PCB thickness input
Fixed error in previous version's external conductor calculation
Version 4.1.1
Added skin depth to the fusing current portion of the conductor calculator
Version 4.1
Added skin depth to the conductor calculator
Version 4.0.1:
Increased Signal slider bar for wavelength to 1/20
Changed default values for planar inductor calculator
Fixed text in BGA land diameter calculator