spacer
 

Fire on the Web


Fire Safety for the Holidays

The National Fire Protection Association (NFPA) reports that there is an estimated annual average of 210 home structure fires that begin with Christmas trees.   Based on data from 2002 through 2005, these fires caused an average of 24 civilian deaths, 27 civilian injuries, and $13.3 million in direct property damage per year [1].

The NFPA analysis also shows that although the number of Christmas tree fires is low, these fires represent a higher level of hazard.  On average, 1 of every 9 Christmas tree fires resulted in a fatality compared to an average of one death per 75 non-confined home structure fires overall.  Further, 49 % of Christmas tree fires spread beyond the room of origin.  The fires that spread beyond the room of origin caused 94 % of the associated fatalities [1].

The percentage of trees involved in structure fires represent an extremely small portion of the total number of natural Christmas trees sold, which is estimated at 30 million trees, in the United States each year [2].  The moisture content of each tree can play a dominant role in determining the fire hazard each tree represents. 

Properly maintaining a cut Christmas tree is important to retaining a high moisture content in the needles of the tree to limit accidental ignition and prevent rapid flame spread.  A tree which has dry needles can readily ignite with a flaming source and generate heat release rates that are capable of causing flashover in residential scale rooms. 

       
  Christmas Tree Fire Video Presentation
  Watch Video   Download Videos
   

Tree Fire Video Clip (QT, 2.3 MB)
Tree Fire Video Clip (MPEG, 4.6 MB)
Tree Fire Video Clip (Real Media, 246 KB)
Tree Fire Video Clip (AVI, 2.4 MB)

This video demonstrates the how quickly the fire can develop when a DRY tree is exposed to an open flame. 
       
  Wet trees tell a different story.  For comparative purposes, the NIST researchers selected a green Scotch pine, had it cut in their presence, had an additional two inches cut from the trunk's bottom, and placed the tree in a stand with at least a 7.6 liter water capacity.  The researchers maintained the Scotch pine's water on a daily basis.  A single match could not ignite the tree.  A second attempt in which an electric current ignited an entire matchbook failed to fire the tree.  Finally they applied an open flame to the tree using a propane torch.  The branches ignited briefly, but self-extinguished when the researchers removed the torch from the branches.  Trees that have been watered properly, and maintain pliable, green needles are harder to ignite than dry trees with needles that break easily when bent and fall from the tree when the branches are shaken.  
       
  Dry Tree vs. High Moisture Tree Fire
 
  Watch Video   Download Video
    Comparison of dry tree and properly maintained (high moisture) tree fires (WMV, 8.6 MB) *** (Text Transcript)
  This video shows the ignition propensity of a properly maintained tree compared to that of a dry Fraser fir tree.    
       
  Dry Tree Fire without a Sprinkler System
  Watch Video   Download Videos
    Dry tree fire in non-sprinklered room (camera view-couch) (WMV, 11.8 MB) (Text Transcript)

       
    Dry tree fire in non-sprinklered room (camera view-outside room) (WMV, 11.6 MB)
  These videos show the effect of a dry tree on a non-sprinklered furnished room.    
       
Dry Tree Fire with a Sprinkler System
  Watch Video   Download Video
    Dry tree fire in sprinklered room (camera view-couch) (WMV, 26.4 MB) (Text Transcript)
  This video demonstrates the impact of a single residential sprinkler on a dry tree in a furnished room.    
       
 

For Holiday Fire Safety tips, please refer to the United States Fire Administration
www.usfa.fema.gov/safety/tips/holiday.shtm

and the Maryland State Fire Marshal
www.firemarshal.state.md.us

Information on the heat release rate of Scotch Pine Trees can be found at
fire.nist.gov/bfrlpubs/fire00/PDF/f00147.pdf

Information on the heat release rate of Fraser Fir trees and the impact of a residential sprinkler on the heat release rate can  found at
www.fire.nist.gov/bfrlpubs/fire08/art014.html
 
*** A high resolution video (broadcast quality) can be obtained by contacting Dan Madrzykowski at madrzy@nist.gov.

       
 

References:

  1. Ahrens, M., Home Christmas Tree and Holiday Light Fires.  National Fire Protection Association, 1 Batterymarch Park, Quincy, MA, November 2007.