The Fluorescence Solutions Company |
|
|
|
|
|
|
|
Home > Products
QuantaMaster™ Series
|
QuantaMaster™ 300 — Phosphorescence/Fluorescence Spectrofluorometer
The QuantaMaster™ 300 Phosphorescence/Fluorescence spectrofluorometer utilizes a pulsed xenon source for excitation, which allows not only spectral and kinetic fluorescence and phosphorescence measurements, but also the measurement of lifetimes greater than 1 µs. The QuantaMaster™ 300 has a detection limit of 50 femtomolar, a signal to noise ratio of 1,500 to 1 and a rep rate from 1 to 300 Hz! |
Back to top. |
|
|
QuantaMaster™ 300 Plus — Phosphorescence/Fluorescence Spectrofluorometer
The QuantaMaster™ 300 Phosphorescence/Fluorescence spectrofluorometer utilizes a pulsed xenon source for excitation, which allows not only spectral and kinetic fluorescence and phosphorescence measurements, but also the measurement of lifetimes greater than 400 nanoseconds. The QuantaMaster™ 300 Plus has a signal to noise ratio of 3,000 to 1 and a minimum measurable lifetime of 1 µs (with deconvolution)! |
Back to top. |
|
|
QuantaMaster™ 310 — Phosphorescence/Fluorescence Spectrofluorometer
The QuantaMaster™ 310 Phosphorescence/Fluorescence spectrofluorometer utilizes a pulsed Nitrogen pumped dye laser source for excitation. The QuantaMaster™ 310 has a minimum measurable lifetime of 1 µs (with deconvolution) and a data acquisition rate of up to 20 points/sec!
|
Back to top. |
|
|
QuantaMaster™ 400 — Intensity Based Spectrofluorometer
The QuantaMaster™ 400 steady state spectrofluorometer is the most sensitive bench-top fluorometer on the market today. It’s signal to noise is 20,000:1 and with a 460 attomolar sensitivity, the QuantaMaster™ 400 allows even the most minute traces of fluorescent materials to be detected and identified in mixtures.
|
Back to top. |
|
|
QuantaMaster™ 500 — NIR with InGaAS Spectrofluorometer
The QuantaMaster™ 500 NIR steady state spectrofluorometer Is based on TE-cooled InGaAs detectors. The QuantaMaster™ 500 has a wavelength coverage from 500-1700 nm (optional up to 3200 nm) and a sensitivity of singlet oxygen generated by 1 µM Rose Bengal in MeOH.
|
Back to top. |
|
|
QuantaMaster™ 510 — NIR with InGaAS Spectrofluorometer
The QuantaMaster™ 510 is the system for you if you need intensity based NIR measurements at a very LOW COST!
|
Back to top. |
|
|
QuantaMaster™ 520 — NIR with InGaAS Spectrofluorometer
The QuantaMaster™ 520 is the system for you if you need intensity based NIR measurements at the spectral range extended up to 3200 nm.
|
Back to top. |
|
|
QuantaMaster™
600 — NIR with PMT Spectrofluorometer
The QuantaMaster™ 600 NIR steady state spectrofluorometer Is based on PMT detectors. The QuantaMaster™ 600 is available in four models for maximum spectral coverage and offers the potential for future fluorescence and phosphorescence lifetimes upgrades.
|
Back to top. |
|
|
QuantaMaster™ 800 — Rapid Excitation Spectrofluorometer
The QuantaMaster™ 800 UV VIS Rapid Excitation is the latest high-speed multi-wavelength ratio fluorescence system from PTI. It incorporates our patented DeltaRAM X™ random access monochromator for into our standard steady state spectrofluorometer to allow for rapid ratiometric measurements. With the QuantaMaster™ 800 you can get up to 250 Ratios per second!
|
Back to top |
|
TimeMaster™ Series
|
LaserStrobe™ TM-3000 — Time-Resolved Spectrofluorometer
The LaserStrobe™ time-resolved fluorescence lifetime spectrofluorometer utilizes PTI’s pulsed nitrogen and dye lasers as an excitation source, which provides unsurpassed excitation wavelength coverage from 240 nm (frequency doubler option required) to 990 nm. The TM-3000 uses PTI’s patented Stroboscopic Lifetime Technique, the simplest, fastest and the most direct way of measuring fluorescence lifetimes. PTI's LaserStrobe can measure lifetimes from 100 ps to 50 ms and decays of 7pM fluorescein. |
Back to top |
|
|
TimeMaster™ LED
TM-2000 — Strobe Lifetime Spectrofluorometer
The TimeMaster™ TM-2000 is an L-format cuvette-based lifetime spectrofluorometer capable of making fast and simple fluorescence lifetime measurements down to 100 picoseconds! With Wavelength coverage from 260 to
670 nm, the TM-2000 spectrofluorometer is designed for the user who needs the most versatile and modular L-format system for the time-resolved fluorescence spectroscopy using a LED light source. |
Back to top |
|
|
TimeMaster™ Microscopy TM-50 — Microscope-Based Fluorescence Lifetime Spectrofluorometer
The TimeMaster™ microscope-based fluorescence lifetime spectrofluorometer utilizes PTI’s pulsed nitrogen and dye lasers as an excitation source, which provides unsurpassed excitation wavelength coverage from 240 nm (frequency doubler option required) to 990 nm. Very intense pulses make it ideal for weak samples, while the low repetition rate prevents photodecomposition. The TM-50 uses PTI’s specially designed photometer in conjunction with a patented fluorescence lifetime detection system. |
Back to top |
|
|
PicoMaster 1000 — TCSPC Lifetime Fluorometer
The PicoMaster 1000 is an L-format cuvette-based lifetime spectrofluorometer capable of making fast and simple fluorescence lifetime measurements down to 40 picoseconds (light source and detector dependent). The PicoMaster 1000 spectrofluorometer has LED wavelength coverage from 266 to 572 nm and Laser Diode coverage from 633 to 667 nm. |
Back to top |
|
RatioMaster™ Series
|
RatioMaster™ — Fluorescence Microscopy
The RatioMaster™ is a microscope-based ratio spectrofluorometer for the collection and analysis of ratio-metric photometry data for calcium, pH, and intracellular ion and FRET! The RatioMaster™ can collect up to 1000 points per second and 250 ratios per second and has an adjustable band pass from 0 to 24 nm. |
Back to top |
|
|
RatioMaster™ SL200 — Fluorescence Microscopy
The RatioMaster™ SL-200 is a microscope-based ratio spectrofluorometer capable of single wavelength dynamic fluorescence measurements on a microsecond timescale. The ScopeLite 200 excels in providing a powerful illumination source for dyes in comparison with the DeltaRam™ as the ScopeLite is a metal Halide CW light source with a direct input to the microscope using a 2 m, 3 mm core liquid light guide. |
Back to top |
|
ImageMaster™ Series
|
EasyRatioPro — Fluorescence Imaging System
The EasyRatioPro is fluorescence imaging perfect. The patented Warp Drive Imaging™ interface allows you to efficiently gather superb quality data allowing researchers to get control back into their research. |
Back to top |
|
|
EasyRatioPro
SL200 — Fluorescence Imaging System
This is the lowest cost imaging system in the EasyRatioPro family. It allows researchers to perform high speed, single wavelength fluorescence imaging experiments using dyes like Fluo4, DAPI, FITC, TexasRed and a multitude of single wavelength fluorescence probes. The illumination source (ScopeLite 200) is a 200 watt metal Halide continuous white light source.The ERP-SL200 system is also fully upgradable to the Patented PTI DeltaRam™X multiwavelength illuminator.
| | | | |