13:20 |
Comissioning Yagmur just called and said "to go upto 0.46 probe Voltage and backoff if we get in trouble". Gradient now set to 0.46. |
2595
|
|
01/14/2016 13:20:24 |
Comissioning
|
|
|
Alfred Moretti
Yagmur just called and said "to go upto 0.46 probe Voltage and backoff if we get in trouble". Gradient now set to 0.46.
|
|
|
|
12:58 |
Operations/RF/805MHz Cavity vacuum hasn't quite baselined yet but is close. |
2594
|
|
01/14/2016 12:58:16 |
Operations/RF/805MHz
|
|
|
Yagmur Torun
Cavity vacuum hasn't quite baselined yet but is close.
|
|
ModularCa..6.tiff |
|
|
|
|
|
12:21 |
Comissioning AM on duty; The last spark occurred at 4:04 am. That is over 300 k pulses without a spark. What is the plan????? |
2593
|
|
01/14/2016 12:21:58 |
Comissioning
|
|
|
Alfred Moretti
AM on duty; The last spark occurred at 4:04 am. That is over 300 k pulses without a spark. What is the plan?????
|
|
|
|
10:51 |
Operations/RF/805MHz We were down briefly due to a crowbar trip. We are back up and running now. |
2592
|
|
01/14/2016 10:51:37 |
Operations/RF/805MHz
|
|
|
Ben Freemire
We were down briefly due to a crowbar trip. We are back up and running now.
|
|
|
|
09:16 |
Operations/DAQ Dave stopped by to investigate why the "Probe V of Last Spark" box in "Spark Statistics to Acnet Writer.vi" was not updating. The conclusion is that the vi is frozen, and can be reset the next time LabView is restarted. As a result, the "Pulses since Last Spark" is also not updating. The "Total pulse counter" in the main vi must now be used to keep track of the number of pulses. |
2591
|
|
01/14/2016 09:16:33 |
Operations/DAQ
|
|
|
Ben Freemire
Dave stopped by to investigate why the "Probe V of Last Spark" box in "Spark Statistics to Acnet Writer.vi" was not updating. The conclusion is that the vi is frozen, and can be reset the next time LabView is restarted. As a result, the "Pulses since Last Spark" is also not updating. The "Total pulse counter" in the main vi must now be used to keep track of the number of pulses.
|
|
|
|
07:54 |
Operations/RF/805MHz Shift summary: one spark with max. probe voltage limit at 0.45 V. |
2590
|
|
01/14/2016 07:54:06 |
Operations/RF/805MHz
|
|
|
Terrence Hart
Shift summary: one spark with max. probe voltage limit at 0.45 V.
|
|
|
|
04:47 |
Operations/RF/805MHz spark #30 for pulse #2258493. |
2589
|
|
01/14/2016 04:47:34 |
Operations/RF/805MHz
|
|
|
Terrence Hart
spark #30 for pulse #2258493.
|
|
|
|
04:00 |
Operations/RF/805MHz Terry Hart starts shift. Instructions are to maintain max. probe voltage limit of 0.45 V. |
2588
|
|
01/14/2016 04:00:49 |
Operations/RF/805MHz
|
|
|
Terrence Hart
Terry Hart starts shift. Instructions are to maintain max. probe voltage limit of 0.45 V.
|
|
|
|
03:48 |
Operations/RF/805MHz Modulator trip (IGN_I_ST), reset without changing drive level (which was down due to the last spark anyway). |
2587
|
|
01/14/2016 03:48:04 |
Operations/RF/805MHz
|
|
|
Yagmur Torun
Modulator trip (IGN_I_ST), reset without changing drive level (which was down due to the last spark anyway).
|
|
|
|
03:46 |
Operations/RF/805MHz Attention shifters: please HOLD @ 0.45V probe peak until further notice. |
2586
|
|
01/14/2016 03:46:58 |
Operations/RF/805MHz
|
|
|
Yagmur Torun
Attention shifters: please HOLD @ 0.45V probe peak until further notice.
|
|
|
|
03:39 |
Operations/RF/805MHz I occasionally notice what looks like the waveforms momentarily shifting to the left on LeCroy and Tek7104 in my peripheral vision, not sure what to make of it. |
2585
|
|
01/14/2016 03:39:44 |
Operations/RF/805MHz
|
|
|
Yagmur Torun
I occasionally notice what looks like the waveforms momentarily shifting to the left on LeCroy and Tek7104 in my peripheral vision, not sure what to make of it.
|